dyuKan

Ɲɛfɔli fɛsɛfɛsɛnin min be kɛ ka ɲɛsin fɛnw ma minw be bɔ yɔrɔ minw na, u datugunin lo-

Feb 04, 2026

ci

 

Nɛnɛbɔli sankaso min datugunin lo - (min be weele fana ko nɛnɛbɔlan ɲagaminin -circuit de cooling tower) ye nɛnɛbɔlan ɲuman ye min be yɛlɛma fila ɲɔgɔnna minw be yɛlɛma yɛlɛma ani yɛlɛma ɲɔgɔndan. A be nafa minw sɔrɔ nɛgɛjuru datuguninw ka funteni yɛlɛmani na ani yɛlɛmani min be kɛ ni pakew ye, u fara ɲɔgɔn kan.

 

A ka yɛlɛmani barikaman n’a ka funteni yɛlɛmani ɲuman fɛ, a be baara kɛ kosɔbɛ iziniw ka funteni doni caman yɔrɔw la ani a bɛnnin lo ka baarakɛcogo sifa caaman nɛnɛ.

The Impact Of The Belt And Road Initiative On The Development Of Closed-Circuit Cooling Towers

Labɛncogo jɔnjɔn ani baarakɛcogo sariyakolo

 

 

 

 

Minɛnw kɔnɔyɔrɔ ye fila -circulation système ani fɛn jɔnjɔnw ye, ni labɛncogo ye min be funteni yɛlɛmani ɲuman ni jii-marali baara kɛ ka bɛn ɲɔgɔn ma.

 

O fɛnw ye fɛn jɔnjɔnw ye: nɛgɛdaga datugunin min be funteni yɛlɛma, nɛgɛdaga, PVC nɛgɛdaga, vantilatɛri ni fiɲɛbɔlan, jii minɛyɔrɔ, nɛgɛdaga, nɛgɛdaga pɔnpe ani nɛgɛdaga min be baara kɛ ni hakiliman ye. Fiɲɛ min be bɔ, o ye cross flow ye coil yɔrɔ la ani counter flow ye pack yɔrɔ la, o min be kɛ funteni yɛlɛmani flow ɲɔgɔnna ye.

 

 

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

 

O fila -circulation processus ye a ka baarakɛcogo jɔnjɔn ye: kɔnɔna circulation kɔnɔ, processus jii, tulu ani fɛn wɛrɛ minw ka kan ka sumaya, olu be jigi coil datugunin kɔnɔ, k’a sɔrɔ u tɛ ɲɔgɔn sɔrɔ ni kɛnɛma diɲɛ ye processus bɛɛ kɔnɔ, ka nɔgɔw bali ka nɔgɔ ani medium tununi, ani funteni be yɛlɛma water fɛ spray outside pill fɛ; kɛnɛma joli bɔyɔrɔ la, pɔnpe min be jii fiyɛ, o be jii bɔ boon kɔnɔ ani k’a fiyɛ cogo kelen na nɛgɛdaga sanfɛ walisa ka jii filimu bɔ.

 

Ni jii filimu be tɛmɛ pake kɔnɔ, a be fiɲɛ min donna ka bɔ gɛrɛfɛ wala duguma, o be maga a la pewu ani funteni be bɔ yen jii ka yɛlɛmani fɛ ani funteni yɛlɛmani fɛ min be kɛ ni hakiliman ye.

 

 

 

Do You Know How A Closed Circuit Cooling Tower Cools Down Equipment?(1)

 

 

 

Fiɲɛ jiman ani kalaman be bɔ sanfɛla fan fɛ ani jii nɛnɛnin min be fiyɛ, o be kɔsegi ka don jii nɔgɔyɔrɔ la walisa k’a labɛn kokura, o min be jii dɔɔni dɔrɔn lo ɲini ka fara a kan walisa a ka yɛlɛma ani ka yɛlɛma.

 

 

Jii minɛlan be se ka jii bugun minɛ ka ɲɛ fiɲɛ kɔnɔ, ka jii bonya hakɛ kɔlɔsi min ka dɔgɔ ni 0,001% ye, ani ka jii marali ni minanw latanga cogo bɛnnin na.

 

 

Nafa jɔnjɔnw ani baarakɛcogo danyɔrɔw .

 

 

 

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

 

 

 

 

Ni an y’a suma ni kuruwa saniyalen-ji ye ani .Jatelan saniyanin-ji datugunin-nɛnɛ sankansow,nafaba be jikuru sifa min na, o ye fɛn ye min be ɲɔgɔn sɔrɔ. A fɔlɔ, a be se ka funteni yɛlɛma cogo ɲuman na. O la, a be se ka kɛ ko mɔgɔw be ɲɔgɔn minɛ cogo min na, o be dɔ fara funteni yɛlɛmani kan ni 10%-20% ye n’u y’u suma ni sankaso saniyaninw ye, o min b’a to a be se ka kɛ baarakɛyɔrɔw la minw ka funteni ka ca ani doni caaman be yen.

 

 

How does the closed cooling tower achieve water-saving effects?

 

 

 

A filanan, a be se ka yɛlɛma yɛlɛma cogo caaman na. O nɛgɛdaga datugunin be se ka baara kɛ ni fɛɛn caaman ye i n’a fɔ jii saniyanin, tulu ani jii nɔgɔnin, k’a to a be se ka nɛgɛdagaw bali ka oksidi ni tiɲɛni kɛ. A sabanan, a be jii ni kuran mara. O fɛn min be yɛlɛmayɛlɛma, o be dɔ bɔ jii minɛli la kosɔbɛ ani fan be se ka kɛ ni frekansi yɛlɛmani ye walisa ka teliya yɛlɛma ka kɛɲɛ n’a makoya ye ani ka dɔ bɔ kuran minɛli la. A naaninan, a be se ka yɛlɛma yɛlɛma duguma.

 

 

Ni an y’a suma ni counter-flow towers ye minw ka doni kelen lo, a ka bonya ka dɔgɔ ani a bɛnnin lo yɔrɔ minw na yɔrɔ ka dɔgɔ.

How efficient is the closed-circuit cooling tower?

 

A danyɔrɔw ye sɔngɔ n’a ladonni ye ka tɛmɛ: minɛnw labɛncogo ka gwɛlɛ ka tɛmɛ, ani u dilanni musakaw ka ca ni nɛnɛbɔlan gansanw ye minw datugunin lo-; nɛgɛjuruw ni nɛgɛjuruw labɛncogo fila be ladon tuma o tuma, i n’a fɔ nɛgɛjuruw ka sɛgɛsɛgɛri ani nɛgɛjuruw ka nɔgɔ sɛgɛsɛgɛ, o be na ni ladonni baara ni musakaw caya dɔɔni; a man ɲi yɔrɔ gwɛlɛw la, buguri ni gazi caaman be yen minw be se ka nɔgɔya kɛ ka pakew datugu ani ka bobine tiɲɛ.

 

 

 

 

Kow minw be se ka kɛ ani baarakɛyɔrɔw ka baarakɛcogo

 

 

A ka baarakɛcogo ɲuman n’a ka latanga hakɛ cɛmancɛ kosɔn, a be baara kɛ kosɔbɛ ni yɔrɔ caaman ye minw be se ka nɛnɛ.

 

Customer Site Installation of Closed-Circuit Cooling Tower

 

 

Kuranko la, a be kɛ ka tulu sumaya sɛnɛfɛnw ni yɛlɛmalanw na ani ka jii yɛlɛmayɛlɛma funteni dɔgɔya;

kemikali baara la, a ka ɲi ka kɛ nɛnɛko yɔrɔw ye minw be kɛ ni fɛnw ye minw be kɛ ni fɛnw ye minw be se ka mɔgɔw lasun u ka fɛnw nɔgɔ;

nɛgɛko ni masinko baarakɛyɔrɔw la, a be kɛ ka jitulu ni tulu nɛnɛ walisa ka baarakɛminanw baara kɛ cogo basiginin na;

ka fara o kan, a be se ka kɛ fana fiɲɛminɛyɔrɔw la, batiri kuraw ka kuran marayɔrɔ nɛnɛ ani koo wɛrɛw la,kɛrɛnkɛrɛnniya la, a bɛnnin lo baarakɛyɔrɔw ma minw be nɛnɛko ɲuman ɲini ani ka yɔrɔ datuguninw latanga.

 

 

Closed-Circuit Cooling Tower Manufacturing Facility

 

O la, a ka kan ka kɛ ko mɔgɔw be ɲɔgɔn minɛ cogo min na, o be se ka kɛ sababu ye ka funteni yɛlɛmani ɲuman kɛ ani ka yɔrɔw labɛn ka ɲɛ. Hali ni a sɔngɔ ka ca ani a ladonni ka ca, a bele ye minɛn ɲuman ye min ka di mɔgɔw ye doni caman na ani yɔrɔ minw na nɛnɛ be kɛ yɔrɔ caaman na. Ni kuran-marali fɛɛrɛ kura ye, a ka ɲɛtaga siraw i n’a fɔ frekansi yɛlɛmani kɔlɔsili ani -kɔrɔsi kɛlɛli yɛlɛmani bena baarakɛcogo bonya tugun.

A’ ye ɲiningali kɛ .